Argion :
Water-mixable silver-reinforced glass ionomer filling cement
Indications
- Core build-up
- Restoration of deciduous teeth
- Build-up fillings and lining
Features
- Very good radiopacity
- Continuous high fluoride release
- High compressive strength
- Simply mixed with water
- All ingredients pre-dosed in powder form
- No overacidification
Packaging
- 1 x 15g Powder with dropping bottle
Direction to Use
- Argion’s adhesion to enamel and dentine prevents marginal leaks and creates retentions. Undercuts give additional hold to the filling. The layer thickness of the fillings should be at least 1 mm.
- Clean the cavity (for instance with a 3 % hydrogen peroxide) and then rinse carefully with water and dry with an air jet. If the remaining dentine is thicker than 1.5 mm, no additional lining is necessary.
- To avoid pulp irritations which may occur in case of insufficient dentine thickness, covering of the areas near the pulp with calcium hydroxide is recommended.
- Attention! Mix Argion only with water. Shake powder well before use
- Apply Argion at room temperature (19 °C – 23 °C). In case of high temperatures using a cooled glass plate is recommended.
- Place Argion powder on a glass plate or suitable mixing pad and mix the powder portion by portion into the water. Use 1 drop of water for 1 level measuring scoop of powder (this corresponds to a mixing ratio of powder/water = 7 : 1).
- When dispensing the water, hold the dropper bottle in an absolutely vertical position, making sure that the metal cannula protrudes approx. 2 – 3 mm above the top.
- Do not use drops for mixing that flow out when tilting the bottle. A strong plastic spatula or another abrasion resistant spatula should be used for mixing. Mix on a glass plate or other nonabsorbent surface. Start mixing in larger portions and continue with smaller ones.
- Mixing time is approx. 50 – 60 s. Do not exceed 1 min.
- Argion can be worked for approx. 2 min. from the end of the mixing procedure (room temperature). Argion’s setting time is approximately 2 – 3 min after the filling has been inserted into the cavity.
- The working area must be kept dry during the filling procedure. Application of rubberdam is recommended. Linings and build-up fillings can be carefully worked after setting (approximately 4 – 6 min after insertion).
- Fillings should be at least 1 mm deep. Prevent feather-shaped margins. When in doubt, prepare in a conventional way.
- Argion is susceptible to water contamination during the setting phase. Immediately cover the filling with a strip, matrix or a protective varnish after application.
- Rough excess material should be removed immediately. Upon removal of the strips or matrix, the filling must be completely covered again with protective varnish.
- In fillings, finishing and contouring (flexible disc) should be done no earlier than 15 min after application. Repeat varnish and allow to set. The best results for final polishing are obtained 24 h after the filling has been inserted
Reviews